HD Video Surge Protector

STR201V-HD

STR201V-HD

1-CH Video Surge Protector
Features
●Single Channel Video Surge Protector
●Standard:IEC61643-21:2000
●Video Signal (Width>1.3Ghz)
●Multilevel protection: Overvoltage protect ,large Flow capacity 
   Low limiting voltage, faster Response,less Insertion loss
●Ground connection: directly to ground
●Nice Design, mini size,easy to installation
Working Principle:
Surge protector link with the equipment which be protected in the
front of the system, when transmission lines were happen to the
lightning and other instantaneous overvoltage shock, the impulse
current through the surge protector protection branch will discharge
into the earth, and the output voltage limit in the device allow voltage
range. Ensure the safety of operation equipment.


 
Specifications:
Temperature:-40℃~70℃;
Relative humidity≤95%;
Atmospheric pressure70kPa~106 kPa.
Nominal working voltage Un: 5V
Max continuous operation voltage Uc: 6V
Nominal discharge current In(8/20ms): 5KA
Max discharge current Imax(8/20ms): 10KA
Protection level Up( 10/700/ms): <20V
Insulation resistance MΩ: ≥0.4
Insertion loosed dB: ≤0.5
Bandwidth FG: (0.3~12)M
Transmission rate Vs: 10 M
Response time Ta: ≤1ns
Interface type(optional ): BNC( K/K),
Protection level: IP20
Dimension: 26*26*83.5mm(Include BNC Interface)
Material: Aluminum
Installations, Use and Maintenance


Installation steps
*Before connecting the protector to the system, Make sure
 heck grounding resistance and conform to the criteria with
 he requirements;
*Connect the protector to the front of the device firmly.
*Use the short and thick grounding lines as possible as you can
 to connect with the Earth-termination system.



Note:
*There are IN and OUT icons marked on the protector, and
  he OUT port should be connected with the protected device,
  please don’t make mistake. Or it will cause damage to the protector,
  and also the device can’t be protected as expect.
Due to sockets connected interface factors caused the loss of poor,
  should be replace the protector or maintenance.
Users Can’t removes the fasteners part of the device, in order to avoiding
   damage and affect the normal work.


 
Protector examination
*Use the Multi-meter with "Ω × 1" range to measure the protector’s
  resistance, the value should be around 3.5 Ω ; If not, protector need to be
  replaced.
*Use the Multi-meter with "Ω × 10K" range to measure the middle line to
  earth-ground resistance, the value will be around 400KΩ, if not ,need to
  replace the protector.



Connection diagram


Class Date Title Download
Datasheet 2017-06-16 STR201V-HD